8035-1

GUDE

Details

8-fold switched and outlet-metered PDU

Enquire
Category: Tag:

Additional information

Brand

Expert Power Control 8035 for more operational security and energy efficiency in 19-inch installations
  • Demonstrably fewer and shorter outages of your critical IT and AV infrastructure
  • Detect AV and IT problems at an early stage: Through proactive power monitoring per port and environment monitoring
  • Measurably increased energy efficiency (Green IT and AV): Electricity cost and CO2 savings through controlled switching off of devices
  • Integrate anywhere: Quickly and easily integrate anywhere with API interface: REST API, HTTPS, SNMP, Telnet and MQTT
  • Fix AV and IT problems quickly and effectively: Remote reboot or with the self-healing function (automatic restart) thanks to integrated watchdogs
Key Features
  • Event and schedule controlled switching
  • Precise current metering per power outlet of up to 9 units and residual current
  • 2 connectors for plug-and-play sensors
  • Simple and quick mounting due to integrated mounting straps
  • NTP function can be activated
  • Integrated overvoltage protection type 3
Switching function
  • Each power port can be switched via HTTP(S), SNMP, ModbusTCP or command line interface via Telnet, SSH, MQTT and serial interface
  • Programmable on/off sequences for remote reboots (Remote Reboot)
  • Power ports can be switched when preset sensor thresholds are exceeded
  • Self-healing function thanks to 8-channel watchdog: Each power port can be assigned its own Watchdog (ICMP/TCP), which initiates an automatic restart if necessary
  • Switching state and switch-on delay up to 9999 seconds (166 minutes) individually adjustable for each output port after power failure
  • Current peaks due to increased inrush currents are automatically prevented by sequential switch-on with a latency of 1 second
  • Integrated type 3 overvoltage protection (L-N, L/N-PE), status retrievable via network
  • High-inrush relay: max. 4 sec: 30 A /max. 20 ms: 80 A
  • Measurement of key electrical parameters: current (A), voltage (V), phase angle, power factor, frequency (Hz), active power (W), apparent power (VA) and reactive power (VAr)
  • Measurement of residual current type A (mA)
  • Encrypted communication through SSL (TLS 1.1, 1.2, 1.3) and SSH
  • 19-inches, 1 HU
  • LxWxH: 43.9 x 17.8 x 4.4 cm (without mounting brackets)
  • Weight: approx. 2.9 kg
  • Operating temperature: 0-50 °C
  • Storage temperature: -20 – 70 °C
  • Relative humidity: 0 – 95 % (non condensing)
Electrical Connections
  • 1 power supply IEC C20 (max. 16 A, 230 V) for 8035-1/-2/-3
  • 1 power supply IEC NEMA 5-15 (max. 15 A, 120 V) for 8035-6
  • 8 power ports IEC C13 (max. 10 A) for 8035-1
  • 8 power ports IEC C13 Lock (max. 10 A) for 8035-2
  • 8 power ports Safety socket type F (max. 16 A) for 8035-3
  • 8 power ports NEMA 5-15 (max. 12 A) for 8035-6
  • 1 Ethernet connector RJ45 (10/100 Mbit/s)
  • 1 serial interface RS232 (Sub-D, 9-pin)
  • 2 connectors (RJ45) for plug-&-play sensors