Monitoring system with 8 relay outputs and 8 signal inputs
Enquire
Expert Net Control 2304-1 for increased operational reliability and energy efficiency in DIN rail installations
- Demonstrably more security in your critical IT and AV infrastructure
- More control through remote access to individually switchable relay outputs
- Detect AV and IT problems early: Proactive environmental monitoring through plug-and-play sensors
- Integrate anywhere: Quickly and easily integrate anywhere with open API: REST API, HTTPS, SNMP, Telnet, and MQTT
- Defend against physical hazards with connected smoke detectors, leakage sensors and door contacts
Key Features
- Event and schedule controlled switching
- Signal inputs for polling NO/NC devices (e.g. door contact, smoke detector etc.)
- 1 connector for plug-and-play sensors for real-time monitoring
- Easy and fast mounting on mounting rails with top hat profile
- NTP function can be activated
- More flexibility through Radius, Modbus TCP and MQTT 3.1.1 support
Switching function
- Each power port can be switched via HTTP/S, Telnet, SSH, SNMP or command line interface
- Programmable on/off sequences for remote reboots (Remote Reboot)
- Power ports can be switched when preset sensor thresholds are exceeded
- Self-healing function thanks to 8-channel watchdog: The power ports can be assigned its own Watchdog (ICMP/TCP), which initiates an automatic restart if necessary
- Switching state and switch-on delay up to 9999 seconds (166 minutes) individually adjustable for each output port after power failure
- Current peaks due to increased inrush currents are automatically prevented by sequential switch-on with a latency of 1 second
Security
- Generation of status messages via e-mail, syslog, SNMP traps, Telnet, SSH and MQTT depending on set thresholds of the sensor measurement
- Encrypted e-mails (SSL, STARTTLS)
- Access protection by IP access control
- Encrypted communication through SSH
- Secure Login via SSL
- Beeper for audible alarm when sensor limits are exceeded/deceeded
Metering function
- Connection for combined plug-&-play sensors (temperature, humidity and air pressure) to prevent frequently occurring physical hazards such as overheating and increased humidity or air pressure
Operation
- Easy-to-read LED display for displaying total current, IP address , sensor values and error messages
- Firmware update via Ethernet during operation (no restart required)
- Simple and flexible configuration via web browser, Windows or Linux program
- Dynamic assignment of an IP address via DHCP or manual assignment of static IP address
- Convenient control on the go via free GUDE Control+ app (Android and iOS)
- Rapid commissioning thanks to free and reliable drivers from our technology partners
Electrical Connections
- 1 Mains connection with 230 V AC or 30 V DC (terminal clamps)
- 8 switching outputs (terminal clamps)
- 8 passive signal inputs (terminal clamps)
- 1 Ethernet connector RJ45 (10/100 Mbit/s)
- 1 connector (RJ45) for plug-&-play sensors
Technical Details
- Housing form: for mounting rail with top hat profile
- LxHxD: 143 x 65 x 90 mm
- Weight: approx. 400 g
- Operating temperature: 0-45 °C
- Storage temperature: -20 – 70 °C
- Relative humidity: 0 – 95 % (non condensing)
Scope of delivery
- Expert Net Control 2304-1
- Quick start guide