1105-2
GUDE
Details
1-fold switched and metered PDU
Enquire
Expert Power Control 1105 for more security and energy efficiency in IT and AV installations
- Fewer and shorter failures of IT and AV installations
- Detect AV and IT problems at an early stage: Proactive power and environment monitoring
- Increased energy efficiency (Green IT and AV): Reduction of electricity costs and CO2 emissions
- Integrate anywhere: Quickly and easily integrate anywhere with API interface: REST API, https, SNMP, Telnet and MQTT
- Fix AV and IT problems quickly and effectively: Reboot remotely, directly on the device or with an automatic restart thanks to integrated watchdog
Key Features
- Event and schedule controlled switching
- Precise current metering of up to 9 units and residual current
- 1 connector for plug-and-play sensors
- Fast and easy installation
- NTP function can be activated
- High-Inrush relays for high inrush loads
Switching function
- Each power port can be switched via HTTP/S, Telnet, SSH, SNMP or command line interface, as well as via serial interface
- Programmable on/off sequences for remote reboots
- Power ports can be switched when preset sensor thresholds are exceeded
- Self-healing function thanks to 1-channel watchdog: The power ports can be assigned its own Watchdog (ICMP/TCP), which initiates an automatic restart if necessary
- Switching state and switch-on delay up to 9999 seconds (166 minutes) individually adjustable for each output port after power failure
- Current peaks due to increased inrush currents are automatically prevented by sequential switch-on with a latency of 1 second
Metering function
- Power consumption metering (kwH) with 2 energy counters: one counter counts consistently, the other counter is resettable
- Metering of current (A), voltage (V), phase angle, power factor, frequency (Hz), active power (W), apparent power (VA) and reactive power (VAr)
- Metering of differential current type A (mA)
- 1 connectors for combined plug-and-play sensors (temperature, humidity and air pressure)
Security
- Integrated type 3 overvoltage protection prevents damage to the device and connected loads (L-N, L/N-PE), status retrievable via network
- Long-life High-Inrush Relays prevent welding of relay contacts during inrush current peaks
- Generation of status messages (e-mail, syslog and SNMP traps)
- Encrypted e-mails (SSL, STARTTLS)
- Access protection by IP access control
- Encrypted communication through SSH
- Secure Login via SSL
- Beeper for audible alarm when sensor limits are exceeded/deceeded
Operation
- Easy-to-read LED display for displaying total current, IP address and sensor values
- Firmware update via Ethernet during operation (no restart required)
- Simple and flexible configuration via web browser, Windows or Linux program
- Dynamic assignment of an IP address via DHCP or manual assignment of static IP address
- Convenient control on the go via free GUDE Control+ app (Android and iOS)
Electrical Connections
- 1 power supply safety socket type F (max. 16 A, 230 V) for 1105-1
- 1 power supply IEC C14 (max. 10 A, 230 V) for 1105-2
- 1 power port safety socket type F (max. 16 A) for 1105-1
- 1 power port IEC C13 (max. 10 A) for 1105-2
- 1 Ethernet connector RJ45 (10/100 Mbit/s)
- 1 sensor connector (RJ45) für plug-and-play sensors
Technical Details
- LxWxH: 12 x 5.3 x 6.5 cm (without plug socket)
- Weight: approx. 0.3 kg
- Operating temperature: 0-50 °C
- Storage temperature: -20 – 70 °C
- Relative humidity: 0 – 95 % (non condensing)
Scope of delivery
- Expert Power Control 1105-1 / 1105-2
- Connection cable for 1105-2 (safety socket type F – IEC C13), length: 2 m
- Quick start guide